Wind Turbine Generator Enough Power 400W max 600w output+ used for 600W wind turbine 400W solar panels hybrid charge controller
Related Products
Product Features / Advantage
WIND TURBINE GENERATOR

1. 2m/s low wind speed starts the wind turbine generator.
This is the most obvious advange of this wind generator in all of same level product on the market which make high wind energy utilization rate.
2. Three phase AC output
Three phase output can make wind turbine transfer more wind power to electricity. 12V or 24V AC for customers' choise for their system
3. Low fault and strong ability to resist the Typhoon
Fan adopts the unique design of the fuselage shock smooth operation, no noise, the blades with nylon composite materials manufacturing and become, with the optimization of aerodynamic design and structural design, start wind speed is low, high wind energy utilization coefficient, increase the power generating capacity. Stern rudder adopts the design of automatic yaw, stronger ability to resist the typhoon, safe and reliable operation.
4. Horizontal shaft function.
The wind turbine generator can adjust the angle automatically according to the wind directions by the horizontal shaft design.
5. 20-year long service life.
Due to the motor internal labyrinth design, external all fasteners are high strength stainless steel products, so it has better protection effect, can waterproof (IP65), prevent sand more effectively.
6. Easy Installation
Tech Parameters
(If only need Wind Turbine Generator ----link , click the "Model No." to order)! ! ! !
Model No. | Item | ZL1.2-300 | ZL1.3-400 | ZL1.4-500 | ZL1.4-600 |
Power | Rated | 300W | 400W | 500W | 600W |
Max | 450W | 600W | 720W | 830W | |
Voltage | Rated | 12/24 AC | |||
Braked | 14.4/28.8 AC | ||||
Rotor diameter | mm | 1200mm | 1300mm | 1400mm | 1400mm |
Rated Rotate Speed | r/min | 900r/min | |||
Start-up wind speed | m/s | 2m/s | |||
Cut-in wind speed | m/s | 2.6m/s | |||
Rated wind speed | m/s | 12m/s | |||
Cut-out wind speed | m/s | 50m/s | |||
Yaw | fixed-wing type | ||||
Engine | Type | Single-phase Permanent Magnet DC Generator (containing rare earth materials) | |||
Structure | Horizontal shaft | ||||
Equipment surface protection | Aluminum oxide+plastic coating | ||||
Body | Material | Die casting aluminum,one die casting forming | |||
Blade | Number | 3PCS/5PCS (Optional) | |||
Blade material | High strength Carbon fiber with nylon | ||||
Pole diameter | mm | 48mm | |||
Life span | years | 20years | |||
Equipment surface protection | Aluminum oxide+plastic coating | ||||
Working temperature | - 40°C to + 80°C | ||||
Package Weight | G.W | 9Kgs | 9Kgs | 10Kgs | 11Kgs |
Package dimension | LxWxH | 69X32X25CM | 69X32X25CM | 69X32X24CM | 69X32X24CM |
Wind Solar Hybrid Charge Controller

1. The Wind Turbine Generator charging part and Solar charging part are independent with each other, which means that can separately use as Wind Turbine Controller or Solar Controller;
(the light-control function is only suitable for the system containing with solar panels)
2. In the high wind speed or the wind turbine generated power is beyond the scope of the battery and load absorption, the controller can immediately launch the stepless unloading function to protect system equipments;
3. Solar charging part uses the MOS tube technology, which makes the controller with small power-consumption and the whole system more stable;
4. With perfect protection functions, including: anti-lightning, solar reverse-charging, over-voltage automatic-braking, battery reverse-connection and open-circuit protection, etc.

!!! if only need the controller, can click " Model No." to directly purchase !!!
|
800W Wind & 400W Solar | 600W Wind & 400W Solar | 500W Wind & 300W Solar | ||||
System Rated Voltage |
12V/24V Auto-work | ||||||
Solar Panel PV Modules Power |
400W | 400W | 300W | ||||
Wind Turbine Generator Power |
800W | 600W | 500W | ||||
Charging | Max. Current |
80A | 65A | 50A | |||
Average Filling Protection |
14.4V±1% / 28.8V±1% | ||||||
Float Filling |
13.8V±1% / 27.6V±1% | ||||||
Average Filling Recovery |
13.2V±1% / 26.4V±1% | ||||||
Temperature Compensation |
-24mV/℃ / -48mV/℃ | ||||||
Discharging | Disconnect (dc) |
10.8V±1% / 21.8V±1% | |||||
Recovery (dc) |
12.3V±1% / 24.6V±1% | ||||||
Over Voltage |
Cut Off (dc) |
16V±1% / 32V±1% | |||||
Recovery (dc) |
15V±1% / 30V±1% | ||||||
Idle Current (dc) |
≤0.1A | ||||||
Voltage Drop (dc) |
≤0.5V | ||||||
Control Mode |
MPPT charge function, PWM unload function, PWM flow current limiting function | ||||||
Booster Charging |
Flexible independent booster circuit (optional) | ||||||
Display Parameters |
Voltage, charging electric current, storage battery power | ||||||
Display Way |
LCD | ||||||
Protection Type | Lightning protection; Solar reverse charge protection; Battery open-circuit protection; Battery reverse protection; Over wind speed and over-voltage soft automatic brake protection; Overload protection; etc. | ||||||
Cooling Mode |
radiator | ||||||
Environment Temperature |
-25℃~+55℃ | ||||||
Use altitude |
≤5500 m (2000 m above the need to reduce power use) | ||||||
Environment Humidity |
0~90%, not knot de | ||||||
Weight |
1.15KG | ||||||
Shape Dimension | 165*140*64mm |
Connection Diagrames


Wide Application


First-class production and service

World Exhibition

